Details
DI-20 - Multi Indicator
DI-20 has built-in high performance A/D converter & microprocessor which enable multi input signals, output signal transmission, communication, and alarm. As DI-20 is very sensitive measuring instrument, please acknowledge thismanual enough before you start to use it.
Details
1) Input signal: you can choose one out of below table.
Input signal group |
Type |
Input signal range |
Display range |
Symbol |
TC |
B (PR30%) |
|
0~1800℃ |
Tc-B |
R (PR30%) |
|
0~1750℃ |
Tc-R |
S (PR10%) |
|
0~1750℃ |
Tc-S |
K (CA) |
|
-200~1350℃ |
Tc-K |
E (CRC) |
|
-200~800℃ |
Tc-E |
J (IC) |
|
-200~800℃ |
Tc-J |
T (CC) |
|
-200~400℃ |
Tc-T |
N |
|
0~1350℃ |
Tc-N |
RTD |
DIN PT100Ω |
|
-200~600℃ |
DPT1 |
DIN PT(0.1) |
|
-199.9~600.0℃ |
DPT2 |
JIS PT100Ω |
|
0-200~600℃ |
JPT |
DC |
mV |
±50.0 |
-1999~9999 |
MV |
V |
±10.0
0~30V |
-1999~9999 |
V |
mA |
±20.0 |
-1999~9999 |
MA |
*For input of mA, you need to connect external resistor for 250Ω/±0.05%/25ppm.
2) Accuracy: control ±0.2%, transmission output ±0.25% (full scale)
3) Cycle of measurement and display: 200ms (TC, RTD) and 100ms (mV, V, mA)
4) Input resistance: Volt – 400KΩ, mA - 250Ω, others - 1MΩ
5) Signal resistance: PT - 30Ω/Line, others - below 300Ω
6) C.M.R.R: over 140dB, N.M.R.R: over 50dB
7) Alarm: 2 or 4 channels (option)
- Contact capacity: AC 250V/5A, DC30V/5A
- Contact: 1b(N.O)
8) Communication: RS232, RS422, RS485 (option) with builtin terminal resistor
9) Output signal: DC4-20mA / 600Ω (Max) (option) with Insulation of input and output
10) Environment:
- operating -5℃~60℃ / 10%~90%
- storing -20℃~70℃ / 5%~95%
11) Power consumption: 3.5W
12) Power voltage: AC85V~264V
13) Insulation resistance: FG/INPUT, FG/PW, PW/IN(over 100MΩ/500VDC)
14) Weight: about 350g
15) Size(mm): 96(W)X48(H)X100(D)
16) Mounting: PLC multi or single mounting