Order Code |
Description |
User manual |
Operating Temperature |
Series M-Bus Master / BACnet Ethernet Converter |
HD67056-B2-20 |
BACnet Ethernet / M-Bus - Converter
(BACnet Protocols:BACnet Ethernet, BACnet IP - Master M-bus: up to 20 slaves) |
|
-40° to +85° |
HD67056-B2-40 |
BACnet Ethernet / M-Bus - Converter
(BACnet Protocols:BACnet Ethernet, BACnet IP - Master M-bus: up to 40 slaves) |
|
-40° to +85° |
HD67056-B2-80 |
BACnet Ethernet / M-Bus - Converter
(BACnet Protocols:BACnet Ethernet, BACnet IP - Master M-bus: up to 80 slaves) |
|
-40° to +85° |
HD67056-B2-160 |
BACnet Ethernet / M-Bus - Converter
(BACnet Protocols:BACnet Ethernet, BACnet IP - Master M-bus: up to 160 slaves) |
|
-40° to +85° |
HD67056-B2-250 |
BACnet Ethernet / M-Bus - Converter
(BACnet Protocols:BACnet Ethernet, BACnet IP - Master M-bus: up to 250 slaves) |
|
-40° to +85° |
Series M-Bus Master / BACnet MSTP Converter |
HD67056-MSTP-20 |
M-Bus / BACnet MSTP - Converter
(BACnet Protocols: BACnet MS/TP (RS485) - Master M-bus: up to 20 slaves - BACnet Port: RS485) |
|
-40° to +85° |
HD67056-MSTP-40 |
M-Bus / BACnet MSTP - Converter
(BACnet Protocols: BACnet MS/TP (RS485)- Master M-bus: up to 40 slaves - BACnet Port: RS485) |
|
-40° to +85° |
HD67056-MSTP-80 |
M-Bus / BACnet MSTP - Converter
(BACnet Protocols: BACnet MS/TP (RS485)- Master M-bus: up to 80 slaves - BACnet Port: RS485 ) |
|
-40° to +85° |
HD67056-MSTP-160 |
M-Bus / BACnet MSTP - Converter
(BACnet Protocols: BACnet MS/TP (RS485) - Master M-bus: up to 160 slaves - BACnet Port: RS485) |
|
-40° to +85° |
HD67056-MSTP-250 |
M-Bus / BACnet MSTP - Converter
(BACnet Protocols: BACnet MS/TP (RS485) - Master M-bus: up to 250 slaves - BACnet Port: RS485) |
|
-40° to +85° |
Series BACnet IP slave / M-Bus master Converter (specific for heating controllers) |
HD67694-IP-B2-1-10 |
BACnet IP slave / M-Bus master - Converter
( Number of Heating Controllers: 1 , Maximum devices: 10 ) |
|
-40° to +85° |
HD67694-IP-B2-3-25 |
BACnet IP slave / M-Bus master - Converter
(Number of Heating Controllers: 3 , Maximum devices: 25) |
|
-40° to +85° |
HD67694-IP-B2-15-50 |
BACnet IP slave / M-Bus master - Converter
(Number of Heating Controllers: 15 , Maximum devices: 50) |
|
-40° to +85° |
HD67694-IP-B2-30-75 |
BACnet IP slave / M-Bus master - Converter
(Number of Heating Controllers: 30 , Maximum devices: 75) |
|
-40° to +85° |
HD67694-IP-B2-50-100 |
BACnet IP slave / M-Bus master - Converter
(Number of Heating Controllers: 50 , Maximum devices: 100) |
|
-40° to +85° |