HIDRA08MG80000X |
HIDRA08MG8P800X |
HIDRA08MG8P4F4X |
HIDRA08MG800007 |
Interface |
|
|
|
|
Connector |
8 |
8 |
8 |
8 |
Ethernet Ports |
8 x RJ45 |
8 x RJ45 |
4 x RJ45 |
8 x M12 |
SFP Ports |
NO |
NO |
4 x SFP |
NO |
Transmission rate |
10/100/1000BASE-T(X)
auto negotiation speed |
10/100/1000BASE-T(X)
auto negotiation speed |
10/100/1000BASE-T(X)
auto negotiation speed |
10/100/1000BASE-T(X)
auto negotiation speed |
Fiber Ports |
NO |
NO |
100BASE-FX / 1000BASE-X SFP slot |
NO |
PoE support |
NO |
YES |
YES |
NO |
PoE voltage booster |
NO |
YES |
YES |
NO |
Console |
RS232 (RJ45 connector) |
RS232 (RJ45 connector) |
RS232 (RJ45 connector) |
RS232 (A-coding M12 connector) |
Relay Output |
2 relay outputs
with current carrying capacity of 2A @30VDC |
2 relay outputs
with current carrying capacity of 2A @30VDC |
2 relay outputs
with current carrying capacity of 2A @30VDC |
2 relay outputs
with current carrying capacity of 1A @ 24 VDC
(through A-coding M12 connector) |
DIP Switches |
Ring Control |
Ring Control |
Ring Control |
NO |
Reset button |
YES |
YES |
YES |
NO |
Technology |
|
|
|
|
Standards |
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X |
IEEE802.3af / 802.3at for Power-over-Ethernet
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X |
IEEE802.3af / 802.3at for Power-over-Ethernet
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X |
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X |
Flow control |
IEEE802.3x for Flow Control
IEEE802.1D-2004 for Spanning Tree Protocol
IEEE802.1w for Rapid STP IEEE802.1Q for VLAN Tagging
IEEE802.1p for Class of Service IEEE8021X for Authentication
IEEE802.3ad for Port Trunk with LACP |
IEEE802.3x for Flow Control
IEEE802.1D-2004 for Spanning Tree Protocol
IEEE802.1w for Rapid STP IEEE802.1Q for VLAN Tagging
IEEE802.1p for Class of Service IEEE8021X for Authentication
IEEE802.3ad for Port Trunk with LACP |
IEEE802.3x for Flow Control
IEEE802.1D-2004 for Spanning Tree Protocol
IEEE802.1w for Rapid STP IEEE802.1Q for VLAN Tagging
IEEE802.1p for Class of Service IEEE8021X for Authentication
IEEE802.3ad for Port Trunk with LACP |
IEEE 802.1d-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP |
Protocols |
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/
v2c/v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Relay/Client, BootP, TFTP, NTP
Server/Client, SNTP, SMTP, SMTP(Gmail), RMON, HTTP, Syslog, MRP (Client),
LLDP, IEEE 1588 PTP V1/V2, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS,
ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring,
Profinet, Modbus/TCP, UDLD, Security, Trunk,LACP, MLD, 802.1Q VLAN, Port Based VLAN,MAC-
Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN,
QinQ,802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic
ARP Inspection, DHCP relay Agent |
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/
v2c/v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Relay/Client, BootP, TFTP, NTP
Server/Client, SNTP, SMTP, SMTP(Gmail), RMON, HTTP, Syslog, MRP (Client),
LLDP, IEEE 1588 PTP V1/V2, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS,
ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring,
Profinet, Modbus/TCP, UDLD, Security, Trunk,LACP, MLD, 802.1Q VLAN, Port Based VLAN,MAC-
Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN,
QinQ,802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic
ARP Inspection, DHCP relay Agent |
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/
v2c/v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Relay/Client, BootP, TFTP, NTP
Server/Client, SNTP, SMTP, SMTP(Gmail), RMON, HTTP, Syslog, MRP (Client),
LLDP, IEEE 1588 PTP V1/V2, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS,
ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring,
Profinet, Modbus/TCP, UDLD, Security, Trunk,LACP, MLD, 802.1Q VLAN, Port Based VLAN,MAC-
Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN,
QinQ,802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic
ARP Inspection, DHCP relay Agent |
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping,GARP,GMRP, GVRP, SNMPv1/v2c/
v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Server/Relay/Client, DHCP Option
66/67/82, BootP, RARP, TFTP, NTP Server/Client, SNTP, SMTP, SMTP (Gmail),
RMON, HTTP, HTTPS, Syslog, MRP (Client), LLDP, IEEE 1588 PTP V1/V2,
IEEE 1588 Hardware E2E Transparent Clock, 802.1x, EAP, RADIUS, TACACS+,
Mirror port, QoS, ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy
Compatible Ring |
Automation profiles |
Profinet CC-B v2.33 certified,
GSDML file provided |
Profinet CC-B v2.33 certified,
GSDML file provided |
Profinet CC-B v2.33 certified,
GSDML file provided |
Modbus/TCP status registers |
MIB |
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415 |
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415 |
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415 |
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2674 |
Switch Properties |
|
|
|
|
Priority Queues |
8 |
8 |
8 |
8 |
Max. Number of Available
VLANs |
256 |
256 |
256 |
4096 |
VLAN ID Range |
VID 1 to 4094 |
VID 1 to 4094 |
VID 1 to 4094 |
VID 1 to 4094 |
Static IGMP Groups |
256 |
256 |
256 |
128 |
Dynamic IGMP Groups |
256 |
256 |
256 |
256 |
MAC Table Size |
16K |
16K |
16K |
16k |
Packet Buffer Size |
12 Mbit |
12 Mbit |
12 Mbit |
1.5Mb |
Power |
|
|
|
|
Input voltage |
9-48 VDC |
9-48 VDC |
9-48 VDC |
12~57 VDC |
Input current |
3.0A @24V |
3.0A @24V |
3.0A @24V |
1.19A @24V |
Connector |
Removable 5-pin Terminal Block |
Removable 5-pin Terminal Block |
Removable 5-pin Terminal Block |
2 x S-Coding M12 connectors (4 Pin) |
Redoundancy |
YES |
YES |
YES |
YES |
Reverse Polarity Protection |
YES |
YES |
YES |
YES |
Physical characteristics |
|
|
|
|
Housing |
Metal |
Metal |
Metal |
Alluminium, IP67 protection
according to EN 60529 |
Protection level |
IP30 |
IP30 |
IP30 |
IP67 |
Installation |
DIN-Rail |
DIN-Rail |
DIN-Rail |
Wall-mount |
Dimension (WxHxD) |
60.3mm x 137.9mm x 164mm |
60.3mm x 137.9mm x 164mm |
60.3mm x 137.9mm x 164mm |
216mm x 232mm x 72mm |
Weight |
1200g |
1200g |
1200g |
2000 g |
Led indicators |
PWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed, |
PWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed, PoE |
PWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed, PoE |
PWR1, PWR2, Alarm,
Ethernet Act/Link, Ring |
Enviromental |
|
|
|
|
Operating Temperature |
20°C~70°C |
20°C~70°C |
20°C~70°C |
-40°C~75°C |
Storage Temperature |
-40°C~85°C |
-40°C~85°C |
-40°C~85°C |
-40°C~85°C |
Ambient Relative Humidity |
5%~95%, 55°C (Non-condensing) |
5%~95%, 55°C (Non-condensing) |
5%~95%, 55°C (Non-condensing) |
5%~95%, 55°C (Non-condensing) |
Certifications |
|
|
|
|
Safety |
UL60950-1
2nd Ed. /CSA C22.2 No.60950-1-07
2nd Ed. / CB (IEC/EN62368-1 & IEC/EN60950-1) |
UL60950-1
2nd Ed. /CSA C22.2 No.60950-1-07
2nd Ed. / CB (IEC/EN62368-1 & IEC/EN60950-1) |
UL60950-1
2nd Ed. /CSA C22.2 No.60950-1-07
2nd Ed. / CB (IEC/EN62368-1 & IEC/EN60950-1) |
EN 60950-1:2006,
UL/IEC(CB) 61010-2-201 |
EMC |
FCC Part 15, Subpart B, Class A /
EN 61000-6-4:2007+A1:2011 /
EN 61000-6-2:2005 |
FCC Part 15, Subpart B, Class A /
EN 61000-6-4:2007+A1:2011 /
EN 61000-6-2:2005 |
FCC Part 15, Subpart B, Class A /
EN 61000-6-4:2007+A1:2011 /
EN 61000-6-2:2005 |
FCC Part 15, Subpart B, Class A
EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3,
EN 61000-6-2, EN 61000-6-4, |
Rail traffic |
NO |
NO |
NO |
EN50155, EN50121-4, IEC60571, EN45545-2 |
Test |
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11 |
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11 |
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11 |
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11 |
Testing report |
|
|
|
|
Shock |
IEC 60068-2-27 |
IEC 60068-2-27 |
IEC 60068-2-27 |
MIL-STD-810G Method 516.5 |
Drop |
IEC 60068-2-32 |
IEC 60068-2-32 |
IEC 60068-2-32 |
MIL-STD-810F Method 516.5 |
Vibration |
IEC 60068-2-64 |
IEC 60068-2-64 |
IEC 60068-2-64 |
MIL-STD-810F Method 514.5 C-1 & C-2 |
Trafic control |
NEMA TS-2 |
NEMA TS-2 |
NEMA TS-2 |
NO |
RoHS |
YES |
YES |
YES |
YES |
MTBF |
11 years |
11 years |
11 years |
20 years |