EW8BX2A0A33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 LAN, 1 RS485 , 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2D0A33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 LAN, 1 RS485 , 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DRM base (energy meters with external Rogowski coil), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2A0D33 |
Electrical switchboard prepared and configured with: 1 DataManager (3 LANs, 1 RS485, 1 RF868, 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2D0D33 |
Electrical switchboard prepared and configured with: 1 DataManager (3 LANs, 1 RS485, 1 RF868, 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DRM base (energy meters with external Rogowski coil), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2A0B33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 3G interface, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2D0B33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 3G interface, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DRM base (energy meters with external Rogowski coil), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2A0C33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 WiFi, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX3A0000 |
Electrical switchboard prepared and configured with: 3 DTM base (energy meters with external TA), 3PN fuse switch disconnector |
EW8BX3D0000 |
Electrical switchboard prepared and configured with: 3 DRM base (energy meters with external Rogowski coil), 3PN fuse switch disconnector |
EW8BX3C0000 |
Electrical switchboard prepared and configured with: 3 DTM base (energy meters with external TA and RF868), 3PN fuse switch disconnector |
EW8BX3E0000 |
Electrical switchboard prepared and configured with: 3 DRM base (energy meters with external Rogowski and RF868), 3PN fuse switch disconnector |
EW8BX3F0000 |
Electrical switchboard prepared and configured with: 1 DTM (energy meters with external CTs and RF868), 2 DTM (energy meters with external CTs and RS485), 3PN fuse switch disconnector |
EW8BX2B0A33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 LAN, 1 RS485 , 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DTM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2B0B33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 3G interface, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2B0C33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 WiFi, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX2D0E33 |
Electrical switchboard prepared and configured with: 1 DataManager (1 WiFi, 3G, 3 LANs, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DRM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os |
EW8BX3B0000 |
Electrical switchboard prepared and configured with: 3 DTM with 2 I/Os (energy meters with external TA), 3PN fuse switch disconnector |